Burn down transformer
BAUR ATG2
Baur
BAUR ATG2
1
Burn Down Transformer Baur ATG2

Standard set:  burn down transformer ATG 2, HV connection cable (3 m.), earth cable ( 3 m. ), mains supply cord ( 2.5 m.), jumper plug for external emergency stop unit, user manual
Price
Add to Cart
Compare Added
Copy
Existing functions
Main features
Impulse reflection (TDR) cable fault location method

-

Measurement range
n/a
Sampling rate
n/a
Pulse width
n/a
Pulse output voltage
n/a
Propagation velocity (v/2)
n/a
Output impedance
n/a
Secondary and multiple impulse (SIM/MIM) cable fault location method

-

Surge voltage generator
n/a
System coupling module
n/a
Secondary and multiple impulse (SIM/MIM) with DC voltage cable fault location method

-

Surge voltage generator
n/a
System coupling module
n/a
Impulse current cable fault location method

-

Surge voltage generator
n/a
System coupling module
n/a
Surge voltage generator

-

Surge generator output voltage
n/a
Surge pulse energy
n/a
Generation pulse sequence
n/a
DC output voltage range
n/a
DC current output range
n/a
Cable burn down method

+

Output voltage range
0 kV ... 10 kV
Max. output current
32 A rms
Max. load capacity
10 µF
Internal discharge resistance
100 kΩ
Cable sheath testing and fault location

-

Cable sheath test voltage range
n/a
Output current range
n/a
Cable sheath fault prelocation methods
n/a
Voltage measurement range
n/a
Current measurement range
n/a
Audio frequency generator
n/a
Frequency range
Output power
Max. output current
Output impedance
Operating modes
Pin-pointing cable fault location method

-

Additional features
Display
Analogue voltmeter and ampermeter
Operating temperature
-20 °C ... +55 °C
Internal memory
n/a
Battery supply
n/a
Interface

-

Joint location

-

Electric strength
n/a
Special accessories
TDR for cable fault location
n/a
System coupling module with SSG generator
n/a
Surge current coupling module
n/a
Insulation resistance measurement option
n/a
3-phase LV connection cable, 25 m length
471-219
3-phase LV connection cable, 50 m. length
470-809
3-phase measuring cable with connection terminals for test van installation
n/a
Universal receiver
n/a
Ground microphone
n/a
Accessories set for sheath fault location
n/a
Cable Sheath Fault Receiver
n/a
Discharge and grounding rod
GDR 40-250
Surge voltage generator (0 ... 16 kV / 500 Ws)
n/a
Surge voltage generator (0 ... 32 kV / 1100 Ws)
n/a
Surge voltage generator (0 ... 32 kV / 1500 Ws)
n/a
Surge voltage generator (0 ... 32 kV / 2000 Ws)
n/a
Surge voltage generator (0 ... 32 kV / 3000 Ws)
n/a
External auto transformer 110/230 V, 1.5 kVA
n/a
Trolley
n/a
External auto transformator 110/230 V, 3kVA
472-095