Burn down transformer
BAUR ATG 6000
Baur
BAUR ATG 6000
1
The high performance BAUR ATG 6000 burn down transformer is used for impedance reduction of cable faults in low- and medium-voltage networks. The short-circuit proof 5.75 kVA stray field transformer delivers a maximum voltage of 15 kV and is housed in a fully enclosed 19” housing.


Standard set: ATG 6000 burn down transformer, HV connection cable (4 m.), mains supply cable (2.5 m.), earth cable with earth terminal (4 m.), user manual


Price
Add to Cart
Compare Added
Copy
Existing functions
Main features
Impulse reflection (TDR) cable fault location method

-

Measurement range
N/A
Sampling rate
N/A
Pulse width
N/A
Pulse output voltage
N/A
Propagation velocity (v/2)
N/A
Output impedance
N/A
Secondary and multiple impulse (SIM/MIM) cable fault location method

-

Surge voltage generator
N/A
System coupling module
N/A
Secondary and multiple impulse (SIM/MIM) with DC voltage cable fault location method

-

Surge voltage generator
N/A
System coupling module
N/A
Impulse current cable fault location method

-

Surge voltage generator
N/A
System coupling module
N/A
Surge voltage generator

-

Surge generator output voltage
N/A
Surge pulse energy
N/A
Generation pulse sequence
N/A
DC output voltage range
N/A
DC current output range
N/A
Cable burn down method

+

Output voltage range
0 ... 15 kV
Max. output current
90 A rms
Max. load capacity
14 µF
Internal discharge resistance
15 kΩ
Cable sheath testing and fault location

-

Cable sheath test voltage range
N/A
Output current range
N/A
Cable sheath fault prelocation methods
N/A
Voltage measurement range
N/A
Current measurement range
N/A
Audio frequency generator
N/A
Frequency range
Output power
Max. output current
Output impedance
Operating modes
Pin-pointing cable fault location method

-

Additional features
Display
Analogue voltmeter and ampermeter
Operating temperature
-20 °C ... +55 °C
Internal memory
N/A
Battery supply
N/A
Interface

-

Joint location

-

Electric strength
Yes
Special accessories
TDR for cable fault location
N/A
System coupling module with SSG generator
N/A
Surge current coupling module
N/A
Insulation resistance measurement option
On request
3-phase LV connection cable, 25 m length
471-219
3-phase LV connection cable, 50 m. length
N/A
3-phase measuring cable with connection terminals for test van installation
N/A
Universal receiver
N/A
Ground microphone
N/A
Accessories set for sheath fault location
N/A
Cable Sheath Fault Receiver
N/A
Discharge and grounding rod
GDR 40-250
Surge voltage generator (0 ... 16 kV / 500 Ws)
N/A
Surge voltage generator (0 ... 32 kV / 1100 Ws)
N/A
Surge voltage generator (0 ... 32 kV / 1500 Ws)
N/A
Surge voltage generator (0 ... 32 kV / 2000 Ws)
N/A
Surge voltage generator (0 ... 32 kV / 3000 Ws)
N/A
External auto transformer 110/230 V, 1.5 kVA
N/A
Trolley
471-287
External auto transformator 110/230 V, 3kVA
472-096
Add to Cart
Compare Added
Copy

All products, product specifications and data present in this website are subject to change without notice.

About us